 3 Volt Voltage Variable Attenuator 25 dB, DC-2.5 GHz
Features
* * * * * Single Voltage Control: 0 to -3 Volts 25 dB Attenuation Range at 0.9 GHz Low DC Power Consumption SOT-25 Plastic Package Tape and Reel Packaging Available
AT-255 V7
Functional Schematic 1
Vc 5 GND 4
Description
M/A-COM's AT-255 is a GaAs MMIC voltage variable absorptive attenuator in a low cost SOT-25 surface mount plastic package. The AT-255 is ideally suited for use where variable attenuation, fine tuning, and very low power consumption are required. Typical applications include radio, cellular, GPS equipment and automatic gain/level control circuits. The AT-255 is fabricated using a mature 1-micron GaAs MESFET process. The process features full chip passivation for increased performance and reliability.
1 RF
2 GND
3 RF
1. VC = -3 V to 0 V @ 25 A maximum.
Pin Configuration
Pin No.
1 2
Function
RF Port Ground RF Port
Pin No.
4 5
Function
Ground VC
Ordering Information
Part Number AT-255 AT-255TR Package SOT-25 Plastic 1000 piece reel
3
Absolute Maximum Ratings 2
Parameter
Input Power Control Voltage VC Operating Temperature Storage Temperature Absolute Maximum +21 dBm -8 V to +0.5 V -40C to +85C -65C to +150C
Note: Reference Application Note M513 for reel size information.
2. Exceeding any one or combination of these limits may cause permanent damage to this device.
1
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
* North America Tel: 800.366.2266 / Fax: 978.366.2266 * Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 * Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information.
3 Volt Voltage Variable Attenuator 25 dB, DC-2.5 GHz
Electrical Specifications: TA = 25C, Z0 = 50
Parameter
Insertion Loss Attenuation Flatness (Peak-to-Peak) VSWR Trise, Tfall Ton, Toff Transients 3. Insertion loss varies 0.003 dB/C.
3
AT-255 V7
Test Conditions
DC--2.0 GHz DC--1.0 GHz 1.0--2.0 GHz 0.5--1.0 GHz 1.0--2.0 GHz DC--2.0 GHz 10% to 90% RF, 90% to 10% RF 50% Control to 90% RF, 50% Control to 10% RF In Band
Units
dB dB dB dB dB Ratio nS nS mV
Min
-- 23 18 -- -- -- -- --
Typ
3.6 25 20 +7 +5 3:1 10 20 10
Max
4.2 -- -- + 10 +8 -- -- -- --
SOT-25
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
* North America Tel: 800.366.2266 / Fax: 978.366.2266 * Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 * Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information.
3 Volt Voltage Variable Attenuator 25 dB, DC-2.5 GHz
Typical Performance Curves
Relative Attenuation vs. Control Voltage
50MHz 35 1.0GHz 2.5GHz
AT-255 V7
Insertion Loss vs. Frequency
+25C 4 +85C -40C
Insertion Loss (dB)
30
Attenuation (dB)
25 20 15 10 5 0 -3.0
3
2
1
0
-2.5 -2.0 -1.5 -1.0 -0.5 0.0
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Control Voltage (V)
Frequency (GHz)
Maximum Relative Attenuation vs. Frequency
+25C 35 30 +85C -40C
Return Loss vs. Control Voltage @ 900 MHz
S11 0 -5 -10 -15 -20 -25 -3.0 S22
Attenuation (dB)
25 20 15 10 5 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0
S11, S22 (dB)
-2.5
-2.0
-1.5
-1.0
-0.5
0.0
Frequency (GHz)
Control Voltage (V)
Input IP3 vs. Control Voltage
50MHz 30 500MHz
35
Input P1dB vs. Control Voltage
50MHz 500MHz
Compression Point (dBm)
-2.5 -2.0 -1.5 -1.0 -0.5 0.0
25
30 25 20 15 10 5 0 -3.0
IP3 (dBm)
20 15 10 5 0 -3.0
-2.5
-2.0
-1.5
-1.0
-0.5
0.0
Control Voltage (V)
3
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
Control Voltage (V)
* North America Tel: 800.366.2266 / Fax: 978.366.2266 * Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 * Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information.


▲Up To Search▲   

 
Price & Availability of AT-2551

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X